Hot upstairs rooms
A very hot attic radiates heat into upper rooms and makes the air conditioner work harder in summer.

Your attic needs to breathe. Air should come in low at the eaves and leave high near the ridge, carrying heat out in summer and moisture out in winter.
Tell us what you are seeing and we will set up a time to inspect your roof, explain the practical options and give you a written price.
Prefer to talk? Call (316) 742-1900
Our office will contact you shortly to confirm a time. Prefer to talk now? Call (316) 742-1900.
Need help sooner? Call (316) 742-1900. Hablamos Español.
Your attic needs to breathe. Air should come in low at the eaves and leave high near the ridge, carrying heat out in summer and moisture out in winter. When that flow is blocked or unbalanced, shingles age faster, insulation gets damp and upstairs rooms stay hot. Wichita Roofing Pros checks your intake and exhaust and corrects the ventilation, often as part of a roof replacement.
A vented attic is designed to let outdoor air move through it in a steady path.
Intake vents at the soffits or eaves let cooler outside air into the attic at its lowest point.
Exhaust vents near the ridge let warm, moist air out at the top of the attic. The U.S. Department of Energy’s guide to attic air sealing describes this low-in, high-out pattern and notes that continuous soffit vents work best.
Insulation pushed into the eaves can block intake vents. Baffles keep a channel open between the soffit and the attic.
Intake and exhaust need to work together. Too much exhaust and too little intake can pull conditioned air out of the house through ceiling gaps.
Ventilation problems show up in the attic, on the roof and inside the house.
A very hot attic radiates heat into upper rooms and makes the air conditioner work harder in summer.
Frost or water droplets on roofing nails and the underside of the decking mean moist indoor air is reaching the attic and not getting out.
Moisture reduces how well insulation works and can lead to mold.
Excess attic heat can contribute to curling, blistering and premature aging of shingles.
Warm attic air can melt snow on the roof. That water refreezes at the colder eaves and can back up under shingles.
A musty attic or dark staining on the decking points to trapped moisture.
Each type has a role. The right combination depends on your roof shape and attic.
Intake vents in the underside of the eaves. Continuous or evenly spaced soffit vents supply most of the intake air on many homes.
A continuous exhaust vent along the peak of the roof, covered by ridge caps. It lets warm air out along the full length of the ridge.
Low-profile exhaust vents set near the ridge. They are common on hip roofs or roofs with short ridges.
Exhaust vents with spinning heads that use wind to pull air from the attic.
Electric fans that push air out of the attic. They need enough intake to work without pulling air from the living space.
Vents in the gable walls. They can help on some homes but can disrupt airflow when combined with other exhaust types.

More vents are not always better. Different exhaust vents can work against each other.
When two kinds of exhaust vents sit on the same attic, such as a ridge vent and a gable vent or a power fan and a ridge vent, one can pull air in through the other. Air takes the shortest path and skips the lower attic, which leaves heat and moisture behind.
A power fan with too little intake can pull air from the house through light fixtures, attic hatches and other gaps. That wastes cooled or heated air and can draw moisture into the attic.
We look at the vents you have now and recommend a single, balanced approach.
Enter your attic floor area to see the net free ventilating area the IRC starting point calls for.
Planning estimate only, using the balanced 1/300 split with about 45% exhaust. Your local building department decides which code applies, and each vent’s listed net free area is what counts. Book a free inspection and we will measure it for you.
Building codes set a minimum. Your attic layout decides how to reach it.
The International Residential Code sets the minimum net free ventilating area at 1/150 of the attic floor area. That can drop to 1/300 when the ventilation is balanced, with roughly 40 to 50 percent of it provided by exhaust vents high on the roof and the rest by intake vents below. Your local building department decides which code edition applies.
A 1,500-square-foot attic at 1/150 needs about 10 square feet of net free area. At 1/300, with balanced intake and exhaust, it needs about 5 square feet, split between soffit intake and ridge or roof exhaust.
Screens and louvers reduce how much air a vent actually passes. Vent manufacturers list net free area for each product, which is the number that counts.
Many older homes have plenty of exhaust and very little working intake, especially when soffits are solid or blocked by insulation.
Most attic moisture comes from inside the house, not from the roof.
Bathroom fans should vent outside. The Department of Energy’s ventilation guide says kitchen and bathroom vents should never vent into the attic.
Dryer and kitchen exhaust carry a lot of moisture. They need to exhaust outdoors through properly sealed vents.
Gaps around light fixtures, wiring, plumbing and the attic hatch let warm, moist air rise into the attic.
A small roof leak adds moisture too. Stains on the decking around vents or pipes can point to a leak rather than ventilation.
Ventilation works best as part of a system with air sealing and insulation.
The Department of Energy recommends sealing air leaks between the living space and the attic before adding insulation, according to its Consumer Guide to Durable Attics.
When insulation is added, baffles should keep soffit vents open.
Our work focuses on the roof side: intake and exhaust vents, ridge vent installation, soffit vent openings and the roof penetrations themselves. For whole-house air sealing or insulation upgrades, we can point out what we see and suggest you talk with an insulation or energy professional.

A free inspection covers your intake, exhaust and the attic itself, with photos and a written plan.

With the old shingles off, the roof is open and ventilation changes are simpler.
When the ridge is exposed, the decking can be cut back for a continuous ridge vent.
Extra exhaust vents that are causing short-circuiting can be removed and the decking patched.
Soffit vents can be added or opened at the same time if the soffits allow it. See soffit, fascia and trim.
Shingle manufacturers’ installation instructions call for adequate attic ventilation, and poor ventilation can affect warranty coverage. Getting it right protects your investment. Learn more about roof replacement.
We look at the whole path, from soffit to ridge.
We note soffit vents, ridge vents, box vents, turbines, power fans and gable vents.
When accessible, we check for blocked soffits, missing baffles, frost or moisture stains, and where bathroom and kitchen fans vent.
We estimate attic area and compare existing intake and exhaust to what the attic needs.
We recommend a balanced system and explain why, including any vents that should be removed.
You get the scope and price in writing before work begins.
We install the changes, seal the penetrations and show you what was done.

Our weather swings from hot, humid summers to cold winters, and the attic feels both extremes.
On a sunny Wichita afternoon, an unvented or poorly vented attic can get far hotter than the outdoors. That heat bakes the shingles from below and pushes into the rooms underneath.
Cooking, showers and everyday living add moisture to indoor air. When that air leaks into a cold attic, it can condense on the underside of the decking.
A roof that already runs hot ages faster, and aged shingles hold up worse in hail and wind. Good ventilation is one of the ways to help a roof last.
Older houses were often built with different standards, and many have been changed over the years.
Many older homes have solid wood soffits with few or no vents, which leaves the attic with almost no intake.
Years of paint can close the openings in soffit vents.
Blown-in insulation added later often fills the eaves and covers the intake vents unless baffles were installed.
Some roofs have gable vents, box vents, a turbine and a ridge vent all on the same attic, added at different times.

Tell us what you are seeing — a leak, missing shingles, hail damage, gutter overflow or an aging roof. We’ll inspect it, explain the practical options and help you decide what should happen next.
Our office will contact you shortly to confirm a time. Prefer to talk now? Call (316) 742-1900.
Need help sooner? Call (316) 742-1900. Hablamos Español.
Answers come from this website’s information. For an exact price or diagnosis, book a free inspection.